Check fortios-sensor¶
Overview¶
Checks hardware sensor readings (temperature, voltage, fan speed) on FortiGate appliances running FortiOS via the REST API. Alerts when any sensor value crosses the appliance-defined thresholds (lower_non_critical, lower_critical, upper_non_critical, upper_critical). Sensors reporting a value of 0.0 are skipped automatically. Authentication uses a single API token (token-based authentication).
Important Notes:
FortiGate appliances running FortiOS with REST API enabled
Data Collection:
Queries the FortiOS REST API endpoint
/api/v2/monitor/system/sensor-info/selectto fetch all hardware sensor readings and their thresholds
Fact Sheet¶
Fact |
Value |
|---|---|
Check Plugin Download |
https://github.com/Linuxfabrik/monitoring-plugins/tree/main/check-plugins/fortios-sensor |
Nagios/Icinga Check Name |
|
Check Interval Recommendation |
Every 15 minutes |
Can be called without parameters |
No ( |
Runs on |
Cross-platform |
Compiled for Windows |
No |
Help¶
usage: fortios-sensor [-h] [-V] [--always-ok] -H HOSTNAME [--insecure]
[--no-proxy] --password PASSWORD [--timeout TIMEOUT]
Checks hardware sensor readings (temperature, voltage, fan speed) on FortiGate
appliances running FortiOS via the REST API. Alerts when any sensor reports an
alarm condition.
options:
-h, --help show this help message and exit
-V, --version show program's version number and exit
--always-ok Always returns OK.
-H, --hostname HOSTNAME
FortiOS-based appliance address, optionally including
port. Example: `--hostname 192.168.1.1:443`.
--insecure This option explicitly allows insecure SSL
connections.
--no-proxy Do not use a proxy.
--password PASSWORD FortiOS REST API single-use access token.
--timeout TIMEOUT Network timeout in seconds. Default: 3 (seconds)
Usage Examples¶
./fortios-sensor --hostname fortigate-cluster.linuxfabrik.io --password mypass
Output:
Checked 42 sensors, all are ok.
Output (with warnings):
Checked 42 sensors. There are warnings.
* MAC_AVS 1V (0.92 V) is less or equal to a certain threshold (0.9214/0.892)
States¶
OK if all sensor values are within their non-critical thresholds.
WARN if any sensor value is <=
lower_non_criticalor >=upper_non_critical.CRIT if any sensor value is <=
lower_criticalor >=upper_critical.--always-oksuppresses all alerts and always returns OK.
Perfdata / Metrics¶
Depends on the hardware sensors present on your appliance. Each sensor is reported by its ID.
Name |
Type |
Description |
|---|---|---|
<sensor-id> |
Number |
Sensor reading (e.g. |
Credits, License¶
Authors: Linuxfabrik GmbH, Zurich
License: The Unlicense, see LICENSE file.